RSI connection

<< Click to Display Table of Contents >>

Navigation:  Impeller > CFD setup >

RSI connection

Previous pageReturn to chapter overviewNext page

The RSI connection is intended to close the gap between impeller and static components. It provides a simplified, closed volume model for flow simulation neglecting impeller secondary flow path or other casing parts. The RSI connection is added to static components located downstream or upstream to an impeller.

The designed RSI connection will be displayed in the diagram automatically.

(see also Extension)

Possible warnings

Problem

Possible solutions

RSI connection at Inlet/ Outlet cannot be generated.

RSI connection can be generated only if a gap between components exists.

Disable RSI connection or perform corrections at neighbouring component interface if necessary.