Strike velocity

<< Click to Display Table of Contents >>

Navigation:  Impeller > Mean line design > Blade mean lines > Additional views >

Strike velocity

Previous pageReturn to chapter overviewNext page

[pumps only]

The total strike velocity is calculated perpendicularly to the leading edge. The limiting strike velocity (display options) is the maximum strike velocity that can be reached by manipulating the tangential position of the leading edge. Displayed is the meridional leading edge length from hub to shroud versus the strike velocity.